Colorectal cancer is cancer that occurs in the colon or rectum,
and affects both men and women of all racial and ethnic groups, and
is most often found in people aged *0 years or older. For men,
colorectal cancer is the third most common cancer after prostate
and lung cancers. For women, colorectal cancer is the third most
common cancer after breast and lung cancers.
Fecal occult blood should be an important indicator in the
diagnostic evaluation of patients with suspected gastrointestinal
bleeding of any etiology, not just as an indication of colorectal
cancer. The presence of human haemoglobin in faeces is inadequate
as a screening test for stomach cancer (upper gastrointestinal
disorders), because of human haemoglobin derived from the upper
digestive tract is broken down in the intestinal tract (the
antigenicity is lost).
Detection of fecal transferrin, which is more stable in stool than
haemoglobin, provides an alternative way of diagnosing the disease
in the upper digestive tract.
Blood in the stool may be the only symptom of cancer, but not all
blood in the stool is caused by cancer. Other conditions that can
cause blood in the stool include: Haemorrhoids, Anal fissures,
Colon polyps, Peptic ulcers, Ulcerative colitis. Gastroesophageal
reflux disease (GERD). Crohn’s disease, use of non-steroidal
anti-inflammatory drugs (NSAIDs).
The Transferrin Device is a qualitative lateral flow immunoassay for the detection of human transferrin in faeces samples. The membrane is pre-coated with monoclonal antibodies against human transferrin on the test lines region. During testing, the sample reacts with the particles coated with anti-human transferrin antibodies which were pre-dried on the test strip. The mixture moves upward on the membrane by capillary action. In the case of a positive result the specific antibodies present on the membrane will react with the mixture conjugate and generate coloured lines. A red coloured band always appears in the control line and serves as verification that sufficient volume was added, that proper flow was obtained and as an internal control for the reagents.
High performance:
–High Sensitivity: *9%
–High Specificity: *9%
–Ease-to-use
–Reliable results
–Clear backgroud, longer shelf lif
Cat. No. | Description | Package Size | Sample |
---|---|---|---|
AN***7C | Faecal Transferrin Cassette | *5tests/kit | Feces |
AN***7S | Faecal Transferrin Strip | *5tests/kit | feces |